Skip to content

Add higher-order horizontal pressure gradient design doc#448

Open
xylar wants to merge 1 commit into
E3SM-Project:developfrom
xylar:omega/design/add-higher-order-hpg-design
Open

Add higher-order horizontal pressure gradient design doc#448
xylar wants to merge 1 commit into
E3SM-Project:developfrom
xylar:omega/design/add-higher-order-hpg-design

Conversation

@xylar

@xylar xylar commented Jun 28, 2026

Copy link
Copy Markdown

Checklist

@xylar xylar requested a review from sbrus89 June 28, 2026 10:29
@xylar xylar self-assigned this Jun 28, 2026
@xylar xylar added the Design label Jun 28, 2026
@xylar xylar force-pushed the omega/design/add-higher-order-hpg-design branch from 366d4ba to 7e05a15 Compare June 28, 2026 11:12
Comment on lines +68 to +69
surface pressure, and coordinate slope. Convergence rate is a secondary diagnostic, not
the primary acceptance criterion.

Copy link
Copy Markdown
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Convergence rate seems like it should be more than a secondary diagnostic.

Copy link
Copy Markdown
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

We can discuss this. We can have both be equally important acceptance criteria. But I maintain that the point of the higher-order implementation is not primarily to have the higher convergence rate but rather to have a smaller error at resolutions we actually use.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment